ARKEL elevator control system with integrated inverter and control board

Contact

Short Description

 

ARCODE, is a 2-in-1 elevator control system originating from Turkey integrated with a VVVF frequency converter, a microprocessor system, and a rescue system

OUTSTANDING FEATURES OF ARCODE?
• Smooth movement thanks to direct floor arrival
• Short travel time with standard VVVF frequency converter
• Energy saving mode
• Synchronization of the entire Arkel control system
• Compactly designed module system
• Quick, simple installation
• Easy software updates
 
 
 
 
 

ARCODE Technical specifications / Features

Motor / Motor Control Geared & gearless motors
Input voltage (L1,L2,L3) / Power Input (L1,L2,L3) AC 3 Ph., 320-420V, 50/60 Hz AC 3 Ph., 200-240V, 50/60 Hz
Models / Models ARCODE 14, 17 , 26 , 35 , 50 , 75 A
Speed / Speed Maximum 4 m/s
Group connection / Group Operation Maximum 8 elevators
Number of floors / Number of Floors Maximum 64 floors
Communication method / Communication Protocol CANbus
Encoder option / Encoder Options 5V TTL, 10-30V HTL, EnDat, SSI, SinCos, BISS
Safe voltage / Safety Circuit Voltage 48 VAC - 230 VAC

 

 

Contact us for direct consultation and the best product and service pricing. 
LISA CONTROL TECHNOLOGY CO., LTD 
Tel/Fax: +84 24 7309 9997
Address (Office): No. 10 LK10, Ha Tri Service Land Area, Ha Cau Ward, Ha Dong District, Hanoi City
Website:  www.lisatech.vn
  • Specifications
    1. ARCODE TECHNICAL SPECIFICATIONS / TECHNICAL SPECIFICATIONS

      FREQUENCY CONVERTER SYSTEM / DRIVER

      Power Input (L1, L2, L3)

      AC 3 Ph., 320-420V, 50/60 Hz

      AC 3 Ph., 200-240V, 50/60 Hz

      Power Output (U, V, W)

      AC 3 Ph., 0-400V, 0-100Hz

      Model

       

      4B14A

       

      4B17A

       

      4B26A

       

      4C35A

       

      4C50A

       

      4D75A

       

      2B14A

       

      2B17A

       

      2B26A

       

      2C35A

       

      2C50A

      Nom. Output Current (Inom)

      14 A

      17 A

      26 A

      35 A

      50 A

      75 A

      14 A

      17 A

      126 A

      35 A

      50 A

      Max. Output Current (< 6 s)

      28 A

      34 A

      52 A

      70 A

      100 A

      150 A

      28 A

      28 A

      52 A

      70 A

      100 A

      Brake Resistor (B, P)

      50 Ω /

      1 kW

      50 Ω /

      1 kW

      40 Ω /

      1 kW

      25 Ω /

      2 kW

      18 Ω /

      3 kW

      10 Ω /

      6 kW

      50 Ω /

      1 kW

      50 Ω /

      1 kW

      40 Ω /

      1 kW

      25 Ω /

      2 kW

      18 Ω /

      3 kW

      Inbuilt EMC Filters

      DC Reactor EMI/RFI Filter

      DC Reactor

      EMI/RFI Filter

      Evacuation (ES1, ES2)

      60-120VDC Battery Supply Input 220VAC Single Phase Line Supply Input

      60-120VDC Battery Supply Input 220VAC Single Phase Line Supply Input

      MICROPROCESSOR SYSTEM / CONTROLLER

      Supply Voltage

      24VDC (20-28VDC)

      Encoder Options

       

      5V TTL, 10-30V HTL, EnDat, SSI, SinCos, BISS

      Serial Communication

      2 CANBUS (shaft and car)

      3 RS485 (2 Full-Duplex, 1 Half Duplex)

      2 CANBUS (shaft and car)

      3 RS485 (2 Full-Duplex, 1 Half Duplex)

       

      Relay Outputs

      4 Programmable Relay Output (10A@250VAC, 10A@30VDC)

      1 Main contactor Relay Output (10A@250VAC, 10A@30VDC)

      4 Programmable Relay Output (10A@250VAC, 10A@30VDC)

      1 Main contactor Relay Output (10A@250VAC, 10A@30VDC)

      Signal Inputs

      16 Programmable Input (24VDC, 3mA sink)

      Floor Level Magnetic Switches (ML1,ML2)

      16 Programmable Input (24VDC, 3mA sink)

      Floor Level Magnetic Switches (ML1,ML2)

      Transistors Outputs

      4 Programmable Transistor Output (open collector Imax:200mA)

      4 Programmable Transistor Output (open collector Imax:200mA)

      Door Bridging

      Door Bridging Board Connector (reserved)

      Door Bridging Board Connector

      (reserved)

      Cooling

      Air Ventilation and Aluminum Cooler

      Air Ventilation and Aluminum Cooler

      Safety circuit

      48-110-220VAC

      User Interface

      4 Digit Seven Segment plus 8 LED indicator

      4 Digit Seven Segment

      plus 8 LED indicator

      Logging

      SD Card

      SD Card

       

      Contact us for direct consultation and the best product and service pricing. 
      LISA CONTROL TECHNOLOGY CO., LTD 
      Tel/Fax: +84 24 7309 9997
      Address (Office): No. 10 LK10, Ha Tri Service Land Area, Ha Cau Ward, Ha Dong District, Hanoi City
      Website:  www.lisatech.vn

      Features

      - Connection:

      CANbus communication cable connecting the control cabinet and the cabin top cabinet                              

      Standard connection or via CANbus (up to 16 floors)

      • Car position information is connected to the motor's encoder
      • Ability to control 2 independent cabin doors 
      • Rescue system:                
      •  Uses a single-phase 220VAC power source or battery to bring the elevator to the nearest floor or a designated floor
      • Relative encoder (5V TTL or 10-30V HTL) or absolute encoder (Endat, SSI, SinCos or BISS)                            
      • Automatically sets, stores parameters, and monitors information ​                
      • Leveling and early door opening feature                                            
      • High-precision floor leveling
      • All control components can be further programmed
      • Standby mode

      Contact us for direct consultation and the best product and service pricing. 
      LISA CONTROL TECHNOLOGY CO., LTD 
      Tel/Fax: +84 24 7309 9997
      Address (Office): No. 10 LK10, Ha Tri Service Land Area, Ha Cau Ward, Ha Dong District, Hanoi City