Table of Contents

    Most Read

    1-PHASE AND 3-PHASE UPS ARD ELEVATOR RESCUE DEVICE

    Updated: 22/06/2026
    Views: 5008

    Proud to be a representative of major brands from various countrc: Riello - UPS - Italy, SCHNEIDER - Germany, ELIT – Italy – SOJI – China.

    Our products include the following items and equipment:

    • Online, offline, line-interactive UPS… capacity from 1kVA to 800kVA
    • Elevator rescue device 1 pha and 3 pha for elevator motors 3.7-15kW
    • Industrial UPS, industrial inverter, shipbuilding
    • Frequency converter 50Hz to 60Hz or 400Hz, small capacity for household use, enthusiasts of imported audio equipment or vintage fans, etc., and large capacity for the shipbuilding and aviation industries…
    • DC/AC Inverter

     
    WE ARE CURRENTLY SUPPLYING AUTOMATIC RESCUE DEVICES (ARD) UPS ONLINE 1 PHASE, 3 PHASE ARD FOR ELEVATORS
    In the event that the elevator is operating and mains power is lost, the best solution is to use an automatic elevator rescue device (ARD). It provides backup power to bring the elevator to the nearest floor and open the doors for the people inside to exit. This automatic rescue device (backup power source) will automatically recharge when power is restored.
    The elevator rescue device supplies power to the control system and the VVVF frequency converter, running at rescue speed, ensuring 100% rescue capability and extremely smooth operation thanks to the VVVF frequency converter.
     
    BASIC SPECIFICATIONS OF THE 1-PHASE INPUT / 1-PHASE OUTPUT ELEVATOR RESCUE DEVICE (ARD):

    • Input voltage: 220VAC, 1 phase, 50Hz
    • Output voltage: 220VAC, 1 phase, 50Hz
    • Power: 1.5KVA – 2KVA – 3KVA (For elevator motors from 3.7KW to 15KW)
    • Battery voltage: 12Vdc / 24Vdc / 48Vdc

    FJ200N-series-UPS-1-3KVA
     

    BASIC SPECIFICATIONS OF THE 3-PHASE INPUT / 3-PHASE OUTPUT ELEVATOR RESCUE DEVICE (ARD):

    • Input voltage: 380VAC, 3 phase, 50Hz
    • Output voltage: 380VAC, 3 phase, 50Hz
    • Power: 5.5kW to 40kW
    • Battery voltage: 48Vdc / 72Vdc / 96Vdc
    • Technology: IGBT based PWM Sine Wave
    • Integrated ATS automatically switches the power source when power is lost and when it is restored.
    • Extremely simple wiring with just 3 inputs from the grid, 3 outputs to the elevator control cabinet, and 1 control signal

    3-phases-elevator-rescue-devices

    Contact us for direct consultation and the best product and service pricing. 

    LISA CONTROL TECHNOLOGY CO., LTD 
    Tel/Fax: +84 24 7309 9997
    Address (Office): No. 10 LK10, Ha Tri Service Land Area, Ha Cau Ward, Ha Dong District, Hanoi City
    Website:  www.lisatech.vn

    Other Posts