Model |
INV110
5 |
INV110
10 |
INV110
15 |
INV110
20 |
INV110
25 |
INV110
30 |
INV110
45 |
INV110
60 |
Rated power kVA/kW |
5/4 |
10/8 |
15/12 |
20/16 |
25/20 |
30/24 |
45/36 |
60/48 |
|
|
|
|
|
|
|
|
|
INPUT |
|
Nominal voltage |
110Vdc |
Voltage tolerance |
88 ÷ 132Vdc |
Emergency line as option |
400V 3Ph or 230V 1Ph, 50/60Hz
(120, 208, 230, 440, 480 and 575V as option) |
|
|
|
|
|
|
|
|
|
OUTPUT |
|
Voltage |
400V 3Ph+N or 230V 1Ph
(120, 208, 230, 440, 480 and 575V as option) |
Frequency |
50 o 60Hz ± 0.1% |
Static stability |
±1% |
Dynamic stability |
±8% |
Crest factor |
1.414 ±3% |
Working |
Continuously |
Waveform |
Sinusoidal |
Overload |
125% for 10 minutes, 150% for 1 minute |
Transfer time |
20 msec. |
THD distortion |
< 3% |
Efficiency |
> 90% |
|
|
|
|
|
|
|
|
|
MISCELLANEOUS |
|
Operating temperature |
-25 ÷ +50°C |
Relative humidity |
0 from 95% without condensing |
Altitude |
1000m without derating |
Protection degree |
IP20 (IP31, IP41 and IP54 on request)) |
Cooling |
Forced air (natural as option) |
Dimensions (mm) |
400x600x1200 |
600x800x1200 |
800x600x1500 |
Weight (kgs) |
100 |
120 |
130 |
150 |
220 |
270 |
320 |
450 |
|
|
|
|
|
|
|
|
|
STANDARDS |
|
Safety |
IEC/EN 62040-1-1, IEC/EN 60950-1 |
EMC |
IEC/EN 62040-2, IEC/EN61000-3-2, IEC/EN61000-6-2 |
Performance |
EN 62040-3 |
|
|
|
|
|
|
|
|
|
|
|
Model |
INV110
80 |
INV110
100 |
INV110
120 |
INV110
160 |
INV110
180 |
INV110
200 |
INV110
250 |
INV110
300 |
Rated power kVA/kW |
80/64 |
100/80 |
120/96 |
160/120 |
180/144 |
200/160 |
250/200 |
300/240 |
|
|
|
|
|
|
|
|
|
INPUT |
|
Nominal voltage |
110Vdc |
Voltage tolerance |
88 ÷ 132Vdc |
Emergency line as option |
400V 3Ph or 230V 1Ph, 50/60Hz
(120, 208, 230, 440, 480 and 575V as option) |
|
|
|
|
|
|
|
|
|
OUTPUT |
|
Voltage |
400V 3Ph+N or 230V 1Ph
(120, 208, 230, 440, 480 and 575V as option) |
Frequency |
50 o 60Hz ± 0.1% |
Static stability |
±1% |
Dynamic stability |
±8% |
Crest factor |
1.414 ±3% |
Working |
Continuously |
Waveform |
Sinusoidal |
Overload |
125% for 10 minutes, 150% for 1 minute |
Transfer time |
20 msec. |
THD distortion |
< 3% |
Efficiency |
> 90% |
|
|
|
|
|
|
|
|
|
MISCELLANEOUS |
|
Operating temperature |
-25 ÷ +50°C |
Relative humidity |
0 from 95% without condensing |
Altitude |
1000m without derating |
Protection degree |
IP20 (IP31, IP41 and IP54 on request)) |
Cooling |
Forced air (natural as option) |
Dimensions (mm) |
800x800x1800 |
1300x1000x1800 |
1500x1000x1800 |
Weight (kgs) |
600 |
750 |
900 |
1100 |
1300 |
1400 |
1800 |
2000 |
|
|
|
|
|
|
|
|
|
STANDARDS |
|
Safety |
IEC/EN 62040-1-1, IEC/EN 60950-1 |
EMC |
IEC/EN 62040-2, IEC/EN61000-3-2, IEC/EN61000-6-2 |
Performance |
EN 62040-3 |
|